Enables controlling a relay state via user variables. Allows the user variables to be set via Blynk.
Optionally, the servo can have a reset timer to return to its default state after a user definable interval. The interval is set via userVar1.
Replace the WLED06_usermod.ino file in Aircoookies WLED folder, with the one here.
Update the following parameters in WLED06_usermod.ino to configure the mod's behavior:
//Which pin is the relay connected to
#define RELAY_PIN 5
//Which pin state should the relay default to
#define RELAY_PIN_DEFAULT LOW
//If >0 The controller returns to RELAY_PIN_DEFAULT after this time, in milliseconds
#define RELAY_PIN_TIMER_DEFAULT 3000
//Blynk virtual pin for controlling relay
#define BLYNK_USER_VAR0_PIN V9
//Blynk virtual pin for controlling relay timer
#define BLYNK_USER_VAR1_PIN V10
//Number of milliseconds between Blynk updates
#define BLYNK_RELAY_UPDATE_INTERVAL 5000
Вы можете оставить комментарий после Вход в систему
Неприемлемый контент может быть отображен здесь и не будет показан на странице. Вы можете проверить и изменить его с помощью соответствующей функции редактирования.
Если вы подтверждаете, что содержание не содержит непристойной лексики/перенаправления на рекламу/насилия/вульгарной порнографии/нарушений/пиратства/ложного/незначительного или незаконного контента, связанного с национальными законами и предписаниями, вы можете нажать «Отправить» для подачи апелляции, и мы обработаем ее как можно скорее.